THE INTERSECTION OF BRAIN SCIENCE & HUMAN POTENTIALPartner with us
neurofeedback.com
The newsletter
← Research & Evidence
Positive with limitationsRandomized controlled proof-of-concept with a follow-up experiment

Real-Time Neurofeedback Training to Modulate Glutamate-Glutamine Concentration Using Functional Magnetic Resonance Spectroscopy.

Healthy adults receiving accurate feedback learned to shift the measured metabolite signal in the assigned direction. This is a method-development result, not evidence of clinical benefit.

Wang Z, Babu S, Beck N, Frank SM.
NMR in biomedicine · Publication date: 2026-09-21
Added to site: 2026-09-24
DOI: 10.1002/nbm.70399

Electronic publication date verified in the full-text article XML. The indexed MED record lists the November 2026 issue date; first indexed 2026-09-22. This source date is separate from the site's addition date.

Modalities
Neurofeedback, fMRS, MRI
Clinical focus
Glutamate-glutamine, Healthy adults, Method development
Population
Healthy young adults, mean age 23.6 years across the 36 unique participants
Sample
Experiment 1: 30 healthy adults, 15 with veridical feedback and 15 with random feedback; Experiment 2: 15 adults, including nine returning participants and six newly recruited participants
Intervention / method
Thirty real-time fMRS neurofeedback trials using self-selected mental strategies to increase or decrease occipital glutamate-glutamine concentration relative to a reference period
Comparator
Random, non-informative feedback in the first experiment

Clinician summary

Veridical-feedback participants learned to increase Glx in experiment 1, while the random-feedback group showed no significant change. A second experiment supported learned decreases, but it reused nine participants and had no parallel random-feedback arm.

How to interpret the findings

Small healthy sample, one occipital volume of interest and short-term laboratory training. The full text notes possible parallel BOLD changes, post hoc rather than online linewidth correction, no online outlier or frequency/phase correction, motion-related confounding and uncertain generalizability to other regions or clinical populations.

Equipment and disclosures

Single-voxel proton fMRS on a Siemens Prisma 3 Tesla scanner with a 64-channel head/neck coil; 2-second PRESS scans

Supported by the Julitta und Richard Müller Stiftung and the Deutsche Forschungsgemeinschaft Emmy Noether program, grant 491290285. The authors declared no conflicts of interest.

Related evidence

Compare findings from the same clinical area, including mixed results.

Full text checked · Checked 2026-09-24

Summary prepared with AI assistance. Source verification does not imply an independent replication or a clinician's endorsement. Read our review method.