Positive with limitationsSecondary machine-learning analysis of an open clinical recording dataset with epoch-level train, validation and test partitions

Conditional spatial classification of expert-confirmed interictal epileptiform discharge epochs: An EEG-ECG ablation and SHAP analysis.

Adding ECG channels improved internal classification of where already confirmed epileptiform discharges appeared on the scalp. The model did not detect discharges, localize a seizure source or prove that ECG is a clinical biomarker.

Plabon AM, Mukit A, Neyamul M, Jehady OF, Zuba FT, Mina MF, Islam T.
PloS one · Publication date: 2026-09-22
Added to site: 2026-09-26
DOI: 10.1371/journal.pone.0358782

Electronic publication date verified in Europe PMC and the full text; first indexed 2026-09-23. This source date is separate from the site's addition date.

Modalities
EEG, ECG, Machine learning
Clinical focus
Epilepsy, Interictal epileptiform discharges, Signal classification
Population
Clinical EEG recordings from the Epilepsy Center of Peking Union Medical College Hospital
Sample
2,514 expert-confirmed four-second IED epochs from 52 participant recordings containing IEDs within an 84-participant dataset
Intervention / method
Five-class spatial categorization of already confirmed IED epochs using 19 scalp EEG channels, EEG plus two ECG channels or the full 29-channel EEG, referential, ECG and EMG input
Comparator
Channel-set ablation across EEG only, EEG plus ECG and all 29 channels using identical epoch-level partitions

Clinician summary

Best test accuracy was 88.89% with EEG only, 93.25% with EEG plus ECG and 94.44% with all channels. Every directly comparable classifier improved numerically after ECG was added, but the changes were descriptive and not tested with paired statistical comparisons.

How to interpret the findings

The split was epoch-level rather than patient-disjoint, allowing participant-specific information to enter training and test sets. Only expert-confirmed IED epochs were included, so specificity, false-positive reduction and screening were not evaluated. Prior methods were not reimplemented, and the full-channel condition jointly added referential and EMG channels.

Equipment and disclosures

Nineteen international 10-20 scalp EEG channels, four referential channels, two ECG channels and four deltoid EMG channels were available; acquisition hardware was not reported in the checked full text.

The full text states that the authors received no specific funding and declared no competing interests.