MixedOpen-label single-arm safety and feasibility pilot

Safety and feasibility of accelerated deep transcranial magnetic stimulation for stimulant use disorder: A pilot study

Published online October 16, 2026. An intensive 10-day deep-TMS schedule was feasible for some participants and caused no serious adverse events, but craving and stimulant use did not significantly change. Larger sham-controlled studies are needed.

Richard M, Bousseau E, Desbeaumes Jodoin V, Guibene E, Blumberger DM, Baker TE, Assi EB, Dubreucq S, Juster RP, Jutras-Aswad D, Lespérance P, Miron JP.
Psychiatry Research · Publication date: 2026-10-16
Added to site: 2026-10-18
DOI: 10.1016/j.psychres.2026.117538

First published online October 16, 2026; assigned to the January 2027 issue. Added to Neurofeedback.com October 18, 2026.

Modalities
Deep TMS, Accelerated TMS, rTMS
Clinical focus
Stimulant use disorder, Feasibility, Safety
Population
Adults with moderate to severe stimulant use disorder
Sample
19 enrolled, 16 initiated treatment and 12 completed at least 80% of sessions
Intervention / method
Participants received 30 sessions of 20 Hz deep TMS with an H7 coil, delivered as three sessions per day across 10 days to target medial prefrontal and anterior cingulate regions.
Comparator
No sham or active control; outcomes were measured over time

Clinician summary

Twelve of 16 treatment starters completed at least 80% of sessions. No serious adverse events occurred; mild headache affected 75% and fatigue 69%. Depression (P = .020) and withdrawal (P = .033) improved, while anxiety, rumination, craving and stimulant use did not (all P > .05).

How to interpret the findings

Small single-arm open-label pilot with attrition, no sham comparator and multiple exploratory outcomes. Improvements over time cannot be attributed to stimulation, and the clinically central craving and stimulant-use outcomes were null.

Equipment and disclosures

H7 deep-TMS coil; the abstract does not identify the manufacturer. No BrainMaster attribution.

Crossref lists FRQS and CIHR funding. Daniel M. Blumberger reported research support from public and philanthropic sources, BrainsWay grant and in-kind equipment support and sponsor-initiated study roles, MagVenture in-kind equipment, Indivior medication supplies, a Sooma Medical advisory role and unpaid Clinical TMS Society committee membership. Other authors reported no relevant conflicts. No indexed correction, retraction or concern notice appeared in the retained PubMed or Crossref records; this is a bounded check. AI-assisted review.

Related evidence

Compare findings from the same clinical area, including mixed results.

Abstract checked · Checked 2026-10-18

Summary prepared with AI assistance. Source verification does not imply an independent replication or a clinician's endorsement. Read our review method.